Panel Siding | Products | LP SmartSide | LP Building ProductsLearn about LP smartSide siding panels and the advantages of treated wood siding sheets Get the warmth and beauty or natural wood with enhanced durability.

PRECISION SERIES PRIMED PANEL SIDING - LP Building ProductsDo not force siding into place. Maintain the illustrated 3.2 mm space behind the joint to allow for expansion while the panel equilibrates with the local environment. LP smartSide Panel siding must not be attached by stapling. DO NOT INSTALL OVER ALIGNMENT BEAD. Install panels in light contact to the edge of alignment bead. (see above ding). Application instructions (cont.) 4 ft. x 8 ft. Ungrooved Shiplap Panel. LP smartSide Panel siding Joint Details. Double row of nails.

application instructions - LP Building ProductsLP smartSide 38 Series lap siding may be attached directly to framing members that are spaced up to a maximum of 16 in. O.C.. Check your local building code before starting to install the sid- ing to confirm if wall sheathing is required. siding joints should be staggered over successive courses. for installation with or without wood structural panels, joints must occur over stud locations. siding shall be installed with top (blind) nailing, with the nails placed 3/8 in. from either end and ...

Many problems with installations of LP SmartSide siding - Star Tribune6 Oct 2015 ... Overdriven nails. This is another common defect. Here's a small collage of overdriven nails. Overdriven nails. The diagram below shows the appropriate repair methods for overdriven nails. LP smartside Nailing Diagram ... The third option is to have flashing at least 4" wide installed at the joints, as long as the ends of the siding are factory finished, and the siding is prefinished by an approved or preferred prefinisher. That means no cut edges at the butt joints.

application instructions - LP Building Productsfor information on fastening LP smartSide products in high wind speed areas, refer to ICC-ES Report ESR-1301 or APA Product Re- port PR-N124. Alternative Fastening Option for (fiber) Blind Nailing. Limited to 6 and 8 wide lap siding, 9" and wider lap siding. MUST BE face nailed. Wood structural panels must be a minimum 7/16 inch Category with an APA Trademark that contains the consensus Standard. DOC PS 2. Foundations Series lap siding must be fastened with:.

LP SmartSide Trim & Fascia - LP Building Productsof 3 nails per width. for trim over 12 inches wide use a minimum of 4 nails per width. Where edges of trim meet siding material, windows, doors or other finished openings, leave a minimum 3/16 inch space to allow for proper sealing. Provide increased spacing along the trim if specified by the siding application instructions. Do not miter corner joints of band boards, fascia, corner trim, etc. (See diagram 2e). 4a. CUTTING. 4b. Moisture Control. Fastening Instructions. Caulked Butt Joint.

LP SmartSide Panel - LP Building ProductsPrecision 38 and 76 Series panel siding must be installed on. 16 in. O.C. framing only. When installing on 24 in. O.C. framing,. Precision Series 190 Series panel siding is required. In all installations over masonry or concrete walls, the wall shall be furred out and open at the top and bottom of the wall to allow for convective ventilation between framing spaced 16 in. O.C. The framing shall be of adequate thickness to accept 1-1/2 inches of nail penetration. A properly installed ...

How to Install 4 x 8 Siding | Home Guides | SF GateFinish the siding with trim molding, typically 1-by-4-inch boards, around doors and windows and on corners. Put 1-by-4 boards, quarter-round or other molding along the tops of the wall panels and along the bottom to cover the ledger boards. Install batten boards over panel joints for that style of siding. Use finishing nails for trim pieces and set the nail heads. Fill all nail holes, on siding and trim, with wood filler or caulk.

How to Build a Shed - How To Install Exterior LP Siding Panels Part 211 Oct 2013 ... View all 2 replies. View all 2 replies. Hide replies. Greg Bosl3 years ago. I too have watched, enjoyed and used many things in your videos. My question regards the use of glue when using the 5/8" smart Side panels. We paid the extra and purchased the thicker panels.Glue and a few nails would still be your suggestion? I also like the idea of less nails through the panels thus creating less chance for water intrusion. Do you seal the nail heads, can't remember if you ...

Video 8 How To Install LP Smart Side Panels on The ShedThis is the eighth of 15 videos. In this video we will be installing the LP smart Side panels on the front and back of the shed. It may seem odd to install the LP smart Side panels on just the front and back walls but it is an important step and doing things in this order will make things easier as you continue. Henry explains why in this video. LP smart Side panels are not hard to install but there are some things you should know and they are covered in this video. IMPORTANT: Much of the ...

LP Smartside - LP Building ProductsCan I overlap my LP smartSide siding more than the recommended 1? a. Yes but the siding should not project beyond the thickness of the trim. The specified overlap and edge-spacing of the nails in the installation instructions are minimum requirements. Refer to the installation instructions for proper installation. 21. Are there any special considerations when applying any panel siding to the interior of my home and is this application allowed and will my warranty be good? a. Using LP ...

How to Install Panel Siding - Better Homes and GardensHow to Lay Out Panel Sides. nails should be driven into studs. Commonly nails are placed 6 inches apart along the perimeter and 12 inches apart in the middle. Trim overlaps the siding. Use Z-flashing at any horizontal joints. Keep the panels 6 inches above grade and at least 2 inches away from concrete or asphalt stairs or walkways. Gaps may be prescribed where panels join at a shiplap joint and where plywood meets flashings.

How To Install LP SmartSide Trim & Siding (4 of 8): Cedar ...29 Jun 2015 ... Contractors, watch how to install LP smartSide cedar shakes. Also refer to the detailed application instructions at www.lpsmartside.com.

application instructions - LP Building ProductsAND STUCCO PANEL siding. Stud Spacing. Foundations 76 Series soffit may be installed as panel siding. ONLY if the LP Product Description includes Foundations Soffit. Please verify any soffit product selection for use as a siding with .... nailing/8 OC field nailing. Look for the California State Fire Marshal. Office label on our siding. The Louisiana-Pacific Corporation (LP) LP smartSide siding. (the Products) limited warranty (the Warranty) applies only to structures on which ...

LP Smartside Siding Residential Installation by Lindus Construction ...23 Jul 2013 ... forgive my ignorance. I know nothing of the subject but they put a waterproof layer under the siding. Then they shoot thousands of nails through it............................ In my mind, the waterproof layer is then a worthless waste of money.. Read more. Show less. Reply 1 2. Hippie With A Cow